Click to enlarge image
|
Model Number |
TF-200, TF-100 |
Features
- The basic operating principle of our humidifier is centrifugal atomization; water supplied to a quickly spinning rotator becomes fine particles when impact is exerted on the hydrophilic plate. These particles are the blown with strong wind to generate fog particles.
- When fine water particles evaporate, they absorb heat. Using this principle, the humidifier may be used as a cooler for various facilities in summer. In addition to humidity control and cooling capabilities, it is equipped with the capability to adjust spraying volume per hour from 0 liters to 200 (100)liters, allowing it to serve as an excellent sprayer for chemicals and additives.
- If you operate only the blower fan with a wind speed of 10.5m/s, it will also act as an air-circulating unit. In other words, you can maximize the effects from one equipment depending on your purpose.
TF-200 : Installing Option
- separate water supply tank after combined with the body and cart
- reservoir tank is added to Type1
- A rotator is installed in Type2
- Only a rotator is added to Type1
- Fixed onto the ceiling by using the body only.
- Both the body and the rotator installed onto the ceiling; rotating with 90 or 360 degrees.
|
|
|
|
|
TF-200 |
TF-100 |
Fixed on the ceiling | Specification
|
Model |
TF-200 |
TF-100 |
|
Body Dimension(mm) |
700(l) x 700(w) x 700(h) |
500(l) x 500(w) x 500(h) |
|
Body Weight(kg) |
42 |
27 |
|
Spraying Volume(l/h) |
0~200 |
110 |
|
Spraying Distance(m) |
28 |
25 |
|
Particlt Distance(µm) |
0~450(adjustable) |
20~450(adjustable) |
|
Spraying Type |
Centrifugal Atomization |
|
Main Motor power(w) |
382.00 |
133.30 |
|
Blower Motor power(w) |
690.00 |
421.00 |
|
Total Power(w) |
1,072.00 |
555.00 |
|
Voltage |
VAC220, 3-Phase, SIngle |
|
Frequency (HZ) |
60 |
|
Main Motor Rotations |
3,357 RPM |
3,515 RPM |
|
Blower Motor Rotations |
1,500 RPM |
1,623 RPM |
|
Averge Wind Speed(msc) |
10.50 |
10.20 |
|
Water Pressure(kg/cm2) |
7.00 |
7.00 | Installing Place Mushroom Cultivator, Nursery, Galss (green) House, Pigpen, Dairy Barn, Chicken Farm, Disinfection, Industrial Sites, Lawn field (Lawn ground), Outdoor cooling, Cold Storage,
- It may be used as an evaporation cooling system in summer, and humidifying system in winter that will overcome dryness caused by excessive heating. In addition, by spraying chemicals, it may be used throughout all seasons for multi-purposes including epidemic prevention, elimination of offensive odors, and insect control.
- Complete evaporation cooling using the strong wind from the turbo atomizer will create a pleasant environment both for the audience and the players.
|
|
|
|
| |
|
|
|